Coatings & Acessories

Favicol AC Duct King Lag Coating AF 5590

UL classified antifungal vapour barrier & fire retardant costing ideal for protecting insulation against mechanical damage

Favicol AC Duct King Lag Coating AF 5590 is an UL classified, antifungal, vapour barrier & fire retardant coating which protects insulation against fire & flame, mechanical damage, fungal growth & condensation. It is a Green and safe fire resistant coating with low VOC.


Recommended Area of Application

  • Coating is strongly recommended for all insulated HVAC Ducts, Chilled water piping and VRC/VRV piping in internal areas with low realtive humadity

Reason For Recommended

  • Mechanical Protection - Protects insulation material from mechanical damage
  • Fire retardant - prevents spread of flames and smoke generation
  • anti-fungal - prevents fungal growth and help maintain IAQ
  • Vapour barrier - prevents surface condensation and heat loss
  • reduced OPEX - Reduces energy losses, maintainance & reworking cost icrease life of the system
  • Faster completion - reduces labour time and help in faster completion since brush applied

Standard Conformation

  • UL classifiedfor surface burning characteristic (UL 723)
  • Flammability and smoke developed index - ASTM E84
  • Fungal resistance - ASTM D 4804
  • wet flammability resistance - ASTM D 3278
  • water vapour permeability - ASTM E 96
  • IGBC/LEED VOC

Unique Features and Benefits

  • Superior protection against mechanical & abrasion damage
  • better performance compared to laminated protective covering
  • prevents formation of surface cracks on insulated surfaces due to aging
  • prevents spread of flame & smoke
  • multiple application for internal HVAC insulated ducts, VRV/VRF pipes and chilled water pipes
  • Prevents Fungal Growth
  • prevents the probable ingress of VOC present in low engineered through the supply/return air bacause of the light vapour barrier coating
  • available in 15 shades

Type of Building / Application

  • health care & hospitality
  • Pharmaceutical & process industries
  • food & beverage industries
  • green buildings
  • IT/ITES, Commercial & public building & spaces
  • VRC / VRF piping system based Air - conditioned buildings

Recommended method of Application

  • clean the substrate to be coated, so that they are free from dust/rust/oil/moisture
  • stir fevicol AC Duct King lag coating AF 5590 well before use to have a homogeneous material prior to application
  • Apply fevicol AC Duct King Lag coating AF 5590 on insulated surface uniformly by brush
  • immediately wrap glass or canvas cloth tightly with over lapping so that no grap are left and no air pockets are formed
  • immediately apply additional coating on wrapped cloth to achieve smooth, neat coated surface
  • allow to cure for minimum 24 hrs at ambient temperature

Precautions & Limitations

  • Do not dilute. Dilution distorts the product performance
  • keep the container closed when not in use
  • please pre-consult before application in high humidity conditions
  • use of PPE's (protective hand gloves, mask & googgles) is strongly recommended

MSDS is available on request


Typical Data

Appreance : Milky White Thixootroic Opaque paste Viscosity at 30° + 1°C : 500-950 Poise Wet Flammability (D 3278) : No flash to boiling Temperature Resistance : -18°C to 80°C Specific Gravity@30+-1°C : 1.19 to 1.27 % VOC (grms/lit) : <1grms/litre Coverage by brush : 1.5-2msqr/lire/coat (with recommended quality of glass cloth)

(under identical lab test conditions at ambient on smooth nonporous substrates on single side apllication)

Shelf Life & Storage

18 months from the date of manufacture & when stored in a dry and cool place in the original unopened container (Recommended Storage temperature 20°C to 30°C)

Packing

25kg and 5 kg plastic pall


Fevicol Weather Protekt Coat

Monolitic joint free coat for protecting insulation in exposed conditions

Favicol weather protect coat is water based fire retardant, flexible vapour barrier high solid coat which imparts tough mechaniical protection and durable seal against water moisture & weathering. it is ideal for protecting all types of insulation material used in hot and cold insulation used in any type of industrial/HVAC applications

It is specially developed to enhanced the insulation life since it protects the insulation from weathering for longer period of time and imprts special properties like erosion protection water vapour barrier protection ffrom fungal and algal attack. It can be used in exposed exterior and high humidity environments

Recommended Areas of Application

  • Strongly recommended for all HVAC Ducts, Chilled water piping aand VRV / VRC piping insulated with any type of insulation in internal areas and external areas including high relative humadity environment
  • Light indusrial usage on insulated surfaces

Reason for recommended

  • excellent Mechanical protection - Protects insulation material against mechanical damage
  • Weathering resistance - longer life of insulation even in exposed condition
  • excellent longevity - the coated surface does not caulk, crack and chip even in highly exposed conditions
  • water vapour barrier - prevents water ingress below the insulation and preventing corrosion under insulation
  • anti fungal and anti Algal - prevents the fungal growth and Algal attack on coated surface
  • Fire Retardant - Prevent spread of flames and smoke generation
  • Faster Completion - Reduces the labour time and help in faster completion due to brushable system of apllication
  • Reduced CAPEX - Reduced CAPEX as compared to the Sand- Cement Plaster/Aluminium Cladded system
  • Reduced OPEX - Reduced energy losses, maintenance & reworking cost and increases overall system life

Standard Conformation

  • fungal resistance - ASTM D 3273
  • Weathering Resistance - ASTM D 6695
  • surafce flammability - ASTM E 84
  • Resistance to fire at liquid stage - ASTM D 3278
  • content of VOC - EPA 24
  • Resistance to water vapour permeance - ASTM D 3278
  • Algal Resistance - ASTM D 5589
  • Rain water resistance - as per ASTM D 6904
  • Antimicrobial efficiency - ASTM E 2315
  • Fungal Resistance - ASTM G21

Type of Bulding / Application

  • indusrial application
  • oil and gas/chemical industries
  • Pharmaceutical & process industries
  • food & beverage industries
  • health care & hospitality
  • green building
  • IT/ITES, commercial & public building & spaces
  • VRV/VRF piping system based air - conditioned buildings

Recommended method of Application

  • clean the substrate to be coated, so that they are free from dust/rust/oil/moisture
  • For open cell fibrous insulation (glass wool/rock/rock wool)
    • Tightly wrap 10ml glass cloth of recommended quality over the insulation & overlap the joint atleast 5cm. Remove wrinkles,for pipe wrapping usage of glass cloth tape is recommended
    • apply the first coat of weather protect by brush and allow it to cure at ambient for atleast 4-6 hrs
    • post curing apply the second coat of weather protects for smooth and uniform finish
    • for critical application apply 3rd coat after 4-6 hrs at ambient of 2nd coat
    • allow to cure the multi coat system for minimun 24 hrs at ambient temperature
  • for closed cell insulation (Nitrile/EPDM/XLPE)
    • apply first coat of weather protect over insulation by brush uniformly
    • wrap tightly 10 ml glass cloth of recommended quality over the insulation & overlap the joint atleast 5cm
    • remove wrinkles, air pocket for pipe wrapping, usage of glass cloth tape is recommended
    • immediately apply second coat of weather protect for smooth and uniform finish
    • for critical applications apply 3rd coat after 4-6hrs of curing of 2nd coat
    • allow to cure the multi coat system for minimum 24 hrs at ambient temperature
  • Total recommended DFT of coating is 700 to 100

Precautions & Limitations

  • Do not dilute. Dilution distorts the product performance
  • keep the container closed when not in use
  • allow to dry coated surface for 24 hrs before further work avoid application during rain and very high humadity condition to avoid wash off / slow drying issue

MSDS is available on request

Typical Data

appreance : Milky White Thixootroic Opaque paste viscosity at 30° + 1°C : 500-900 poise Wet Flammability (D 3278) : No flash to boiling Temperature Resistance : -18°C to 100°C Specific Gravity@30+-1°C : 1.1 to 1.3 % VOC (grms/lit) : <40 grms/litre Coverage by brush : 1.5-2msqr/lire/coat (with recommended quality of glass cloth)

(under identical lab test conditions at ambient on smooth nonporous substrates on single side apllication)

Shelf Life & Storage

18 months from the date of manufacture & when stored in a dry and cool place in the original unopened container (Recommended Storage temperature 20°C to 30°C)

Packing

25kg and 5 kg plastic pall


Dr. Fixit Silicone Sealant GPS

multipurpose moisture curing, solvent free, acetoxy cure silicone sealant

Dr. Fixit Silicone Sealant GPS is an acetoxy cure, high viscous and single component silicone sealant. when properly cured, it becomes a permanently ealstic compound. it has excellent adhesive to metal and concrete. it is ideal for low temperature in refrigeration sites.

Recommended Areas of Application

  • Ideal for sealing gaps in HVAC ducting between flangers and joints
  • sealing of aluminimum / glass window frame joimts, fixing glass into aluminimum frames in lieu of rubber beading.

Unique features and benefits

  • Non Flammable in uncured condition
  • no mixing is required directly applicable through cartridge
  • no solvent hence eco-friendly
  • completely non-sagging in nature
  • tough & flexible after curing so performs well during expansion & contraction
  • cures by moistures absorbtion from air ambient temperature
  • service temperature - from 60 to 180 C

Recommended method of Application

  • the surface should be made clean, dry and degreased before applying Dr. Fixit silicone sealant GPS
  • fix the making tape on both sides of joint leaving exact gap for filling. this will make joint look good and uniform
  • it is supplied in ready to use plastic cartidges cut nozzle at an angle to desired based size cut the tip of cartidges and fix nozzle load the cartidges into the sealant gun
  • fill the joint with pallet with Dr. Fixit silicone Sealant GPS immediately after filling the joint the sealant should be tooled either with pallet knife or similar tool of required size tooling is essential to remove air bubbles if any and to fill up all volds by the compacting action. this results in proper adhesion to the sides of the joints. ti also gives betteraesthetic surface
  • remove masking tape once the sealant is in touch dry condition
  • after sealing the joint, tool and equipment should be cleaned immediately with kerosene or any other cleaning solvent
  • allow sealant to cure for 7 days minimum at above 50% RH

Precautions & Limitations

  • Avoid usage in food industries for filling gaps
  • do not use where over coating of painting may be done

Typical Data

appreance : clear homogeneous, viscous & soft consistant paste. Also available in black and other colours on request Skinning Time : 10-15 minutes Tack free time : 3hrs Curing Time : approx 24hrs for 2 mm thickness at 30°C & 24 hrs for each further mm Service temperature : from - 60°C to + 180°C Hardness, Shores A : 12-18 Coverage by spreader : once 280 ml cartidges will cover 5 mm width x 5 mm depth joint = 11.2 linear metre / 10 mm width x 10 mm width x 10 mm depth joint = 2.8 linear metre

(under identical lab test conditions at ambient on smooth nonporous substrates on single side apllication)

Shelf Life & Storage

Shelf life is 12 months from the date of manufacturing if stored in original and unopened packaging in a cool dry place away from direct sunlight

Packing

280 ml plastic cartridge with separate nozzle


USSPRO Construction Foam

Single component self-expending polyurethane foam for filling gaps between HVAC duct/chilled water VRC?VRF pipes and doors/window/wall

USSPRO Construction Foam is single component self - expending polyurethane foam used primarily to sell, fill, fix & adhesive to the gaps between HVAC/chilled water/VRV?VRF pipes and doors door/window/wall. Foam is water proof CFC free & environment protective.

Recommended Application Area

  • HVAC Ducts : to seal, fix and adhere the gap between Duct & Structure
  • chilled water pipe : to seal fill, fix and adhere the gap between chilled water pipes & structure
  • VRV/VRF Pipe : to seal, fill, fix and adhere the gap between VRV/VRF Pipes & Structure
  • to repair hole, gap, wall brick, earth brick & to seal, fix and adhere the gap between door, window and wall
  • Sealing of mechanical and electrical penetrations through compartment walls and floors
  • packing and transportation : pack valuable and fragile goods easily, time saving, quick shock and press resistance

Unique Features and Benefits

  • large gap/cavity filler with moisture curing technology
  • can seal gaps even on running chilled water & VRV/VRF pipes
  • excellent sealing on most of construction materials without primer
  • hard foam is developed post curing which is structurally strong
  • expansion of the foam ensures the gap are properly sealed
  • can be used for electrical wirings and cable gap filling and sealing in structure
  • cures itself using moisture in the air/substrate
  • cured foam can be painted/coated to suit the aesthetics

Recommended method of Application

  • ensure all surfaces are free from oli, greases, loose particles and dust
  • shake the canister throughly 20 times approximately before use
  • attach the plastic straw using the screw mechanism on canister firmly and aim straw at gap then spray
  • fill vertical joints from the bottom up
  • while filling the gaps in cealing, uncured foam may drop because of gravity. support extruded foam properly after filling until foam is cured and adhered to the gap
  • allow foam to be tack free for approx, 10 minutes. foam can be cut after 60 minutes os application
  • use a knife to smmoth the cured foam and treat surface with cement, paint or silicone sealant if required

Precautions & Limitations

  • The canister must be capped immediately after use to avoid exposure to atmosphere
  • Remove we strains eith acetone. dry strains can only be removed mechaniically
  • cured foam may turn yellow by direct exposure to UV rays
  • use of PPE's (protective hand gloves, mask & googgles) is strongle recommended

MSDS is available on request.

Typical Data

Density : 15-30 kg/mtsqr Tack free time : 9-13 min cutting time : 60 min approx closed cell : 60-70% temperature resistance : -40°C to +- 90°C yield per 750 ml : 45 litres

(under identical lab test conditions at ambient sprayed in free area)

Shelf Life & Storage

shelf life is 9 months when stored at 20°C from date of manufacturing in factory sealed canister store in cool & dark shaded place away from the sunlight in tightly cloosed condition. Product is packed in canister with pressure of 5-6kg/cm @ 25°CAPEX Ensure that temperature won't exceed 50°C during storage & transportation to avoid explosion

Packing

750 ml Canister

(Due to continuous product improvements, the data mentioned in this TDS herein, supersedes all earlier versions and subject to change without prior intimation)

Catalogue

Click here to download

Contact

For any kind of query, contact us with the details below.

Request a quote